Butyl II 874

Superior Resistance to Highly Corrosive Acids


Product Features

  • Impermeable for working in damp or greasy environments
  • Protection against ketones, alcohols, nerve agents
  • Provides the highest permeation resistance to gases and water vapors of any protective material used to make gloves
  • Unlined to reduce risk of lint contamination
  • Smooth finish
  • Length: 35cm
  • Thickness: 0.35mm
  • Rolled cuff

Certifications

CE
CAT III
EN ISO 374-1:2016 + A1:2018 - TYPE B
EN ISO 374-1:2016
+ A1:2018 - TYPE B
A, B, C, I, K, L, M, N, P, S, T
EN 388:2016 + A1:2018
EN 388:2016
+ A1:2018
2110X
EN ISO 374-5:2016 + A1:2018
EN ISO 374-5:2016
+ A1:2018
Micro Organisms + Virus
EN 388:2016
EN 388:2016
0010X




Features


Further Information

Ideal for those working with biohazards and specifically when handling ketones, amines and esters. The Butyl rubber provides the highest permeation resistance to toxic gases and water vapours.

Available Options

Product Code Size Width Length Height Weight
BST8741 7/S 170 mm 370 mm 10 mm 75 g
BST8742 8/M 200 mm 370 mm 10 mm 83 g
BST8743 9/L 170 mm 390 mm 10 mm 92 g
BST8744 10/XL 170 mm 390 mm 10 mm 100 g
BST8745 11/XXL 170 mm 390 mm 10 mm 122 g

Product Specifics

CoatingButyl
Coating TypeFully Coated
Cuff StyleGauntlet
LinerUnlined/Unsupported
Reusable

Certifications

CE
Cat LevelIII
EN ISO 374-1:2016 + A1:2018 Type BA, B, C, I, K, L, M, N, P, S, T
EN 388:2016 + A1:20182110X
EN ISO 374-5:2016 + A1:2018Micro Organisms + Virus
EN 388:20160010X

EN 388:2016 + A1:2018

Value2110X
Abrasion Resistance
2(1-4)
Cut Resistance (Coup Test)
1(1-5)
Tearing Resistance
1(1-4)

EN 388:2016

Value0010X
Tearing Resistance
1(1-4)

EN ISO 374-1:2016 + A1:2018 Type B

Value A, B, C, I, K, L, M, N, P, S, T
Type B At least 3 chemicals for 30 minutes
A Methanol
B Acetone
C Acetonitrile
I Ethyl Acetate
K Sodium Hydroxide 40%
L Sulphuric Acid 96%
M Nitric Acid 65%
N Acetic Acid 99%
P Hydrogen Peroxide 30%
S Hydrofluoric acid 40%
T Formaldehyde 37%

Options

Selected Option Specifics

SKUBST8741
Size7/S
Main ColourBlack
SKUBST8742
Size8/M
Main ColourBlack
SKUBST8743
Size9/L
Main ColourBlack
SKUBST8744
Size10/XL
Main ColourBlack
SKUBST8745
Size11/XXL
Main ColourBlack

Ordering information

Case Quantity12
Case Quantity12
Case Quantity12
Case Quantity12
Case Quantity12

Packaging

Unit Height10mm
Unit Length370mm
Unit Width170mm
Weight75g
Case height19cm
Case length37cm
Case width16cm
Case weight1.15kg
Unit Height10mm
Unit Length370mm
Unit Width200mm
Weight83g
Case height19cm
Case length37cm
Case width16cm
Case weight1.33kg
Unit Height10mm
Unit Length390mm
Unit Width170mm
Weight92g
Case height19cm
Case length37cm
Case width16cm
Case weight1.29kg
Unit Height10mm
Unit Length390mm
Unit Width170mm
Weight100g
Case height19cm
Case length37cm
Case width16cm
Case weight1.32kg
Unit Height10mm
Unit Length390mm
Unit Width170mm
Weight122g
Case height19cm
Case length37cm
Case width16cm
Case weight1.42kg
Cleaning
To clean, wipe with a damp cloth. Note: the performance characteristics of worn and laundered gloves may differ from the results shown. Inspect the gloves to ensure no damage is present.
Lifetime
Service life depends on the glove application and therefore cannot be specified. It is the responsibility of the user to ensure the glove is suitable for its intended use.
Storage
Store in dry conditions in the original packaging and away from direct sunlight
Recommendations for Use
Chemical resistant glove. Not suitable for cut, heat, thermal, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for cut, heat, thermal, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for cut, heat, thermal, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for cut, heat, thermal, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for cut, heat, thermal, electrical protection. Do not use near moving machinery if there is a risk of entanglement.

You may also like

772 65cm Gauntlet

772

Extended Sleeve Version of Showa 771 Offering Protection From Hand to Shoulder
EN ISO 374-1:2016 + A1:2018 Type B:J, K, L | EN 388:2016 + A1:2018:4111X | EN ISO 374-5:2016 + A1:2018:Micro Organisms | EN 388:2016:4111X
View Product
S-Tex 541 Glove

S-Tex 541

Hagane Steel-Reinforced Cut Resistant Glove
EN 388:2016 + A1:2018:4X41D | EN 388:2016:4X41D
View Product
Nitrile Grip 350R Glove

350R

Grip Glove with Nitrile Coated Palm
EN 388:2016 + A1:2018:4132X | EN 21420:2020 | EN 388:2016:4132X
View Product
707FL Glove

Nitri-Dex 707FL

Food Safe Chemical Resistant Nitrile Glove
EN ISO 374-1:2016 + A1:2018 Type A:J, K, L, O, P, T | EN ISO 374-5:2016 + A1:2018:Micro Organisms + Virus | EN 21420:2020 | ANSI/ISEA 105:2016:X, 6, X
View Product
Butyl II 874
Butyl II 874 Glove

Enquiry for: Butyl II 874

🇬🇧
Compare 0
View Comparison