ASF-2V
FFP2 Disposable Fold-Flat Respirator (Valved)
Product Features
- Lightweight, fold-flat respirator
- Flexible nose bridge
- Inner seal around the nose area for an effective fit
- Electrostatic filter media
- Conforms to EN 149:2001+A1:2009 FFP2 NR
- Available in two size options (regular - AFS and small - ASFS)
- Ideal to fit a wide range of face shapes
- Adjustable loop-through straps
Certifications
CAT III
Features
Further Information
The AlphaFold+ is a vertical fold flat disposable respirator designed with an inner face seal, adjustable straps and two size options to offer an excellent fit for all face shapes.
Product Specifics
| Filter Media Material | Non-Woven Textile |
|---|---|
| Headstrap Material | Latex-Free Elastane, Polyester, Textile Elastic |
| Inner Cover Material | Polypropylene |
| Nosefoam Material | Polyethylene Foam |
| Outer Cover Material | Polypropylene |
| Series | Alphafold+ |
Storage Conditions
| Humidity | <70% |
|---|---|
| Maximum Temperature | 35°C |
| Minimum Temperature | -5°C |
Certifications
| CE | ✓ |
|---|---|
| Cat Level | III |
| EN 149:2001 + A1:2009 | FFP2 NR |
EN 149:2001
| Class | FFP2 |
|---|---|
| Disposable | ✓ |
Selected Option Specifics
| SKU | ASRASF201AF |
|---|---|
| Size | M |
| Main Colour | White |
| Secondary Colour | Orange |
| Shelf Life | 5Years |
| SKU | ASRASF201AD |
|---|---|
| Size | S |
| Main Colour | White |
| Secondary Colour | Orange |
| Shelf Life | 5Years |
Ordering information
| Items per Pack | 15 |
|---|---|
| Case Quantity | 180 |
| Packs Per Case | 12 |
| Units per Pallet | 4320 |
| Items per Pack | 15 |
|---|---|
| Case Quantity | 180 |
| Packs Per Case | 12 |
| Units per Pallet | 4320 |
Packaging
| Unit Height | 220mm |
|---|---|
| Unit Length | 130mm |
| Unit Width | 140mm |
| Pack height | 22cm |
| Pack length | 13cm |
| Pack width | 14cm |
| Weight | 27g |
| Pack weight | 0.27kg |
| Case height | 44cm |
| Case length | 54cm |
| Case width | 24cm |
| Case weight | 3.15kg |
| Unit Height | 220mm |
|---|---|
| Unit Length | 140mm |
| Unit Width | 130mm |
| Pack height | 22cm |
| Pack length | 14cm |
| Pack width | 13cm |
| Weight | 26g |
| Pack weight | 0.26kg |
| Case height | 44cm |
| Case length | 54cm |
| Case width | 24cm |
| Case weight | 3.15kg |
Product Selector Guidance Chart
| Option | Assigned Protection (APF) | Oil/Water Based Particulates | Non-Toxic Dusts | Fine Toxic Dusts/Mists/Fumes | Very Fine Toxic Dusts/Mists/Fumes | Metal Fume |
|---|---|---|---|---|---|---|
| ASRASF201AF | 10 | Recommended | Recommended | Recommended | ||
| ASRASF201AD | 10 | Recommended | Recommended | Recommended |
Parts Dimensions
| Part | Width | Length | Height |
|---|---|---|---|
| Respirator | 125 mm | 160 mm | 10 mm |
| Part | Width | Length | Height |
|---|---|---|---|
| Respirator | 120 mm | 155 mm | 10 mm |
Recommendations for Use
USER INSTRUCTIONS:
Use only in accordance with these instructions, as incorrect use could result in danger to
life or health. Fit according to instructions BEFORE entering the contaminated area.
Discard safely after use or replace with a new respirator if:
• Excessive clogging of the respirator causes breathing difficulty or discomfort
• If the respirator becomes damaged
• The respirator has been worn for 8 hours.
Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined
spaces where gases or aerosols may accumulate and the concentration of contaminant
is immediately dangerous to life or health, (over the IDLH value).
Leave the contaminated area if:
• The respirator is damaged
• You become dizzy or have difficulty breathing
• You become irritated or other distress occurs
• You become uncertain of the nature and/or concentration of contaminant.
WARNING:
• As facial hair reduces the protection offered it is recommended that these respirators
are used by clean shaven personnel only
• Do not use for protection against gases
• Single shift use only
• Do not remove whilst in contaminated area.
Recommendations for Use
USER INSTRUCTIONS:
Use only in accordance with these instructions, as incorrect use could result in danger to
life or health. Fit according to instructions BEFORE entering the contaminated area.
Discard safely after use or replace with a new respirator if:
• Excessive clogging of the respirator causes breathing difficulty or discomfort
• If the respirator becomes damaged
• The respirator has been worn for 8 hours.
Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined
spaces where gases or aerosols may accumulate and the concentration of contaminant
is immediately dangerous to life or health, (over the IDLH value).
Leave the contaminated area if:
• The respirator is damaged
• You become dizzy or have difficulty breathing
• You become irritated or other distress occurs
• You become uncertain of the nature and/or concentration of contaminant.
WARNING:
• As facial hair reduces the protection offered it is recommended that these respirators
are used by clean shaven personnel only
• Do not use for protection against gases
• Single shift use only
• Do not remove whilst in contaminated area.
You may also like
4520
Disposable 3-Panel Fold Flat Respirator - FFP2
EN 149:2001 + A1:2009:FFP2 NR | EN 14683:2019:Type IIR
4530
Disposable 3-Panel Fold Flat Respirator - FFP3
EN 149:2001 + A1:2009:FFP3 NR | EN 14683:2019:Type IIR
ASF-2V
Enquiry for:
ASF-2V
FFP2 Disposable Fold-Flat Respirator (Valved)