Xenon XN135

High Chemical Resistance Gauntlet with Excellent Grip


Product Features

  • A soft, lightweight & robust glove offering great dexterity
  • Triple-coated nitrile provides a strong chemical resistance
  • Superior grip in wet & oily environments
  • Thin nylon liner to improve comfort & reduce sweat
  • Long cuff to provide forearm protection
  • Designed for easy movement & continuous wear
  • No irritation by seams in contact with the skin

Certifications

CE
CAT III
EN ISO 374-1:2016 + A1:2018 - TYPE A
EN ISO 374-1:2016
+ A1:2018 - TYPE A
A, J, K, L, O, P, T
EN 388:2016 + A1:2018
EN 388:2016
+ A1:2018
4121X
EN ISO 374-5:2016 + A1:2018
EN ISO 374-5:2016
+ A1:2018
Micro Organisms
ANSI
A1 6 2
ANSI/ISEA 105:2016
A1 | 6 | 2
EN 388:2016
EN 388:2016
4121X





Further Information

Triple dipped nitrile gauntlet with a nitrile sandy finish palm. Provides excellent grip in wet & oily conditions whilst protecting from chemicals.

Available Options

Product Code Size Width Length Height Weight
SKY00142 8/M 160 mm 410 mm 20 mm 141 g
SKY00143 9/L 170 mm 410 mm 20 mm 132 g
SKY00144 10/XL 170 mm 410 mm 20 mm 143 g
SKY00145 11/XXL 170 mm 410 mm 20 mm 149 g

Product Specifics

CoatingSandy Nitrile, Smooth Nitrile
Coating TypePalm Coated
Construction TypeDipped
Cuff StyleGauntlet
Gauge18
LinerNylon
SeriesXenon
Reusable

Certifications

CE
Cat LevelIII
EN ISO 374-1:2016 + A1:2018 Type AA, J, K, L, O, P, T
EN 388:2016 + A1:20184121X
EN 420:2003 + A1:2009
EN ISO 374-5:2016 + A1:2018Micro Organisms
ANSI/ISEA 105:2016A1, 6, 2
EN 388:20164121X

EN 388:2016 + A1:2018

Value4121X
Abrasion Resistance
4(1-4)
Cut Resistance (Coup Test)
1(1-5)
Tearing Resistance
2(1-4)
Puncture Resistance
1(1-4)

ANSI/ISEA 105:2016

ValueA1, 6, 2
Cut Resistance
A1(A1-A9)
Abrasion Resistance
6(1-6)
Puncture Resistance
2(1-5)

EN 388:2016

Value4121X
Abrasion Resistance
4(1-4)
Cut Resistance (Coup Test)
1(1-5)
Tearing Resistance
2(1-4)
Puncture Resistance
1(1-4)

EN ISO 374-1:2016 + A1:2018 Type A

Value A, J, K, L, O, P, T
Type A At least 6 chemicals for 30 minutes
A Methanol
J n-Heptane
K Sodium Hydroxide 40%
L Sulphuric Acid 96%
O Ammonoim Hydroxide 25%
P Hydrogen Peroxide 30%
T Formaldehyde 37%

Options

Selected Option Specifics

SKUSKY00142
Size8/M
Main ColourGreen
Secondary ColourBlack
SKUSKY00143
Size9/L
Main ColourGreen
Secondary ColourBlack
SKUSKY00144
Size10/XL
Main ColourGreen
Secondary ColourBlack
SKUSKY00145
Size11/XXL
Main ColourGreen
Secondary ColourBlack

Ordering information

Items per Pack10
Case Quantity60
Packs Per Case6
Items per Pack10
Case Quantity60
Packs Per Case6
Items per Pack10
Case Quantity60
Packs Per Case6
Items per Pack10
Case Quantity60
Packs Per Case6

Packaging

Unit Height20mm
Unit Length410mm
Unit Width160mm
Pack height12cm
Pack length41cm
Pack width16cm
Weight141g
Pack weight1.35kg
Case height28cm
Case length52cm
Case width39cm
Case weight9.3kg
Unit Height20mm
Unit Length410mm
Unit Width170mm
Pack height12cm
Pack length41cm
Pack width17cm
Weight132g
Pack weight1.32kg
Case height28cm
Case length52cm
Case width39cm
Case weight9.8kg
Unit Height20mm
Unit Length410mm
Unit Width170mm
Pack height12cm
Pack length41cm
Pack width17cm
Weight143g
Pack weight1.43kg
Case height28cm
Case length52cm
Case width39cm
Case weight10.3kg
Unit Height20mm
Unit Length410mm
Unit Width170mm
Pack height12cm
Pack length41cm
Pack width17cm
Weight149g
Pack weight1.49kg
Case height28cm
Case length52cm
Case width39cm
Case weight10.8kg
Cleaning
To clean, wipe with a damp cloth. Note: the performance characteristics of worn and laundered gloves may differ from the results shown. Inspect the gloves to ensure no damage is present.
Lifetime
Service life depends on the glove application and therefore cannot be specified. It is the responsibility of the user to ensure the glove is suitable for its intended use.
Storage
Store in dry conditions in the original packaging and away from direct sunlight
Recommendations for Use
Chemical resistant glove. Not suitable for heat, thermal, cut, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for heat, thermal, cut, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for heat, thermal, cut, electrical protection. Do not use near moving machinery if there is a risk of entanglement.
Recommendations for Use
Chemical resistant glove. Not suitable for heat, thermal, cut, electrical protection. Do not use near moving machinery if there is a risk of entanglement.

You may also like

4561 Glove

4561

Kevlar Reinforced Cut Resistant Glove with Outstanding Grip
EN 388:2016 + A1:2018:4X32C | EN 407:2020:X1XXXX | EN 21420:2020 | ANSI/ISEA 105:2016:A4, X, X | EN 388:2016:4X32C
View Product
EMG745

EMG745

Cut Level D / A4 Cut Resistant Glove with PU Coating
EN 388:2016 + A1:2018:4X43D | EN 407:2020:X1XXXX | ANSI/ISEA 105:2016:A4, 5, 4
View Product
XC800 Gloves

XC800

Flexible, Lightweight, Latex-Free Design
EN 388:2016 + A1:2018:4X32E | ANSI/ISEA 105:2016:A5, X, X
View Product
TRC230 Glove

TRC230

General Handling Glove With a Unique Textured Nitrile Micro Foam Coating and Recycled Polyester Liner
EN 388:2016 + A1:2018:4121A | EN 407:2020:X1XXXX | EN 21420:2020 | ANSI/ISEA 105:2016:A1, 6, 2
View Product
Xenon XN135
Xenon XN135 Glove

Enquiry for: Xenon XN135

🇬🇧
Compare 0
View Comparison